Difference between revisions of "Factory4 Io Connector"

From RobotinoWiki
Line 7: Line 7:
 
|-
 
|-
 
|Safety
 
|Safety
|Connected to the Sick S300 saftey zone flag output. If low or not connected Robotino's motors are stopped.
+
|Connected to the Sick S300 OSSD1 (Pin3, grey). If low or not connected Robotino's motors are stopped.
 
|-
 
|-
 
|Warning
 
|Warning
|Connected to the Sick S300 warning zone flag output. If low or not connected Robotino's motors are slowed down.
+
|Connected to the Sick S300 UNICI/O4/WF (Pin14, pink). If low or not connected Robotino's motors are slowed down.
 +
|-
 +
|Reset
 +
|Connected to the Sick S300 UNICI/O2/EDM (Pin6, yellow). Reset OSSDs.
 
|-
 
|-
 
|Box available
 
|Box available

Revision as of 15:11, 24 October 2013

Factory4-IO-Connector.png

Connector Description
Safety Connected to the Sick S300 OSSD1 (Pin3, grey). If low or not connected Robotino's motors are stopped.
Warning Connected to the Sick S300 UNICI/O4/WF (Pin14, pink). If low or not connected Robotino's motors are slowed down.
Reset Connected to the Sick S300 UNICI/O2/EDM (Pin6, yellow). Reset OSSDs.
Box available Signal from station indicating that a box can be fetched by Robotino.
Dock complete Signal to station that the docking is completed.

Sick default passwort: SICKSAFE