Introduction

Robotino ea09 icon 64.png Robotinos motor-control board EA09 is capable of sending sensor readings and receiving set point values in realtime at a frequency of 1kHz.

Package links

EA09 Com binary package

EA09 View

EA09 I/O Board

EA09 I/O Board

The EA09 I/O board facilitates the physical connection with Robotino's sensors and motors. The I/O board carries a NXP LPC 2378 micro-controller. The micro-controller's main loop runs at 1kHz. Within this loop the motors' PID controllers are updated.

The micro-controller receives, for instance, the set point values at a rate of about 100Hz from the PC104 via a serial link (RS232). The PID controllers obtain the motors' speed set points (from the PC104) and drive the motors such that the motors' actual velocities equal the speed set points.

EA09 MATLAB Support

EA09 I/O Board and MATLAB

MATLAB drivers for the EA09 I/O Board can be downloaded and installed. These MATLAB drivers consist of m-files which contain functions to send and receive data from the EA09 I/O Board. Simple to understand examples have also been provided to illustrate the use of the MATLAB functions.

EA09View

Robotino matlab icon 64.png A full set of m-Files and Simulink blocks is available for controlling all actuators of Robotino and reading all of its sensors. Download the executable and run the installer.

Package links

EA09 View

EA09View
EA09 I/O Board and EA09View

The EA09View is a simple tool to monitor and control all aspects of the motors via a direct connection to the EA09 I/O board on Robotino.

The rate of 100Hz by which the PC104 reads data from the EA09 I/O Board through the RS232 serial link is too slow to monitor the functioning of the micro-controller on the EA09 I/O Board running the PID controllers. Therefore the I/O Board is equipped with an Ethernet link which allows the micro-controller to transmit all relevant data concerning the PID controllers via UDP to an external PC. The default Ethernet network configuration of the EA09 I/O Board is as follows:

  • IP Address: 172.26.254.254
  • Port: 8809

The EA09View connects to the EA09 Board via the Ethernet link.

EA09View and Robotino® View (Example)

EA09View can be used in parallel with Robotino® View. Since Robotino® View connects with the PC104 on Robotino via WLAN (or LAN) and the PC104 sends the motor speed set-points to the EA09 Board via the serial link (RS232). To use Robotino® View with EA09View make sure the following settings are true for EA09View:

  • Speed Set-point reception is set via Serial line
  • For Motors 0,1 & 2, Motor Monitoring is checked and Motor Control is set to Internal PI Controller

Create a simple program in Robotino® View, for example the one shown below.

EA09View RobotinoView Program.png

In the program above, an arbitrary waveform generates a sine wave and the values are fed directly to the motors as Speed Set-points. Start the simulation in Robotino® View and you should see an output similar to the one below in EA09View.

EA09View